Tcp log view
Tcp log view







tcp log view

Only in rare situations you may want to increase this setting beyond the recommended default value. In general the default 100ms is recommended to have accurate Cloud Logging data and at the same time reduce the impact on the PLC to a minimum. While the IXrouter does wait for the PLC to reply before asking again, in very rare cases this may noticeably impact the PLC's performance. To log data as accurately as possible, the IXrouter continuously asks the variables' values from the PLC (this does not count towards your license's dps/hr).

tcp log view

Variables configured in the IXON Cloud, as well as intermediate addresses, are requested from the PLC, but only the configured variables are logged to the IXON Cloud. This mode may result in errors if intermediate variables do not actually exist in the PLC (please use "Optimized" instead if this is the case). This means that intermediate addresses are included as well. Optimized - Gapped (default): Variables are grouped together in data requests as much as possible for efficient communication. Only variables configured in the IXON Cloud are requested from the PLC and then logged to the IXON Cloud. Optimized: Variables with adjacent addresses are grouped together in data requests. The read mode determines how data is requested from the PLC. The byte order determines how the bytes in a register are translated to a numerical value. The port number will be entered automatically (Port 502 for Modbus).Įnter the Modbus server's slave ID and byte order. The identifier ensures that every data source remains unique, even if they share the same name. Enter the requested information (details below) and click on.Click on the Add a service icon in the left menu, select, and then select.Open the Main menu, go to Devices, and select the concerning device.

tcp log view tcp log view

Go to the IXON Cloud Fleet Manager app, which is accessible from the Apps menu in the top right corner if you are currently in a different IXON Cloud app.This is the protocol that the IXrouter will use to communicate with the PLC. You first have to select a communication protocol. This article shows you how to do this for communication via Modbus TCP. This is done by selecting a communication protocol and defining the variables. The second step in Cloud Logging is setting up a data source. Please first activate Cloud Logging (or start the 30 day free trial) if you haven't already.









Tcp log view